MAINTENANCE
H325 IAE
Rev.: 004
kortho
QiC i-series
10-3
10.3 Weekly maintenance
It is recommended that the system is cleaned and that all connections are checked once a week. In addition
the water separator of the air reduction valve should be monitored for the presence of water content. In that
case, one should relieve the water from the water separator by pressing the shutoff valve at the bottom of the
water separator.
The Health check monitor should be used to ensure the system remains in good condition.
10.4 Half yearly and yearly maintenance
WARNING:
When removing covers all air and mains power should be disconnected.
Every half year the rear cover should be removed to check the condition of the cables and remove any
debris, dirt and dust. Extra attention should be paid to the cleaning of the encoder strip. The encoder strip
should be taken out of the printer and cleaned with a soft nonabrasive cloth.
CAUTION:
Do not use any cleaning solutions as this can permanently damage the encoder strip.
To guarantee a optimal clutch action, and so an optimal ribbon transport, it is adviced to lubricate the clutch
every 6 months with a thin layer of Klübersynth UH1 14-151.
To prevent loss of production it is advisable to service the printer once a year. Only service engineers,
qualified by Korthofah BV, are allowed to service the printer.
10.5 Printhead replacement
WARNING:
The mains power and air supply must be disconnected when replacing the printhead.
CAUTION:
Read Printhead safety notes before handling the thermal printhead. Always ensure anti-static
precautions are observed when handling a thermal printhead or printed circuits boards or they
might get damaged.
CAUTION:
Be careful when touching / exchanging the printhead. The printhead could be very warm and has
some sharp edges on which one can cut oneself.
10.5.1 Printhead safety notes
The enclosed Thermal Printhead is a static sensitive device.
In order to avoid potential damage to the Printhead please ensure anti-static precautions are observed
throughout the installation procedure.
Korthofah cannot be held responsible for damage to the printhead caused by mishandling.
Summary of Contents for qic i series
Page 1: ...MANUAL QiC i series Thermal Transfer Printer Edition H325 IAE Rev 004 English kortho...
Page 14: ...INTRODUCTION kortho QiC i series H325 IAE Rev 004 1 6...
Page 30: ...PRINT PROCESS DESCRIPTION kortho QiC i series H325 IAE Rev 004 3 10...
Page 38: ......
Page 42: ...TRANSPORT STORAGE kortho QiC i series H325 IAE Rev 004 5 4...
Page 110: ...MAINTENANCE kortho QiC i series H325 IAE Rev 004 10 6...
Page 120: ...APPENDIX A SPECIFICATIONS kortho QiC i series H325 IAE Rev 004 A 4...
Page 133: ...APPENDIX C PART LISTS ILLUSTRATIONS H325 IAE Rev 004 kortho QiC i series C 7 Magazine QiC 30i...
Page 159: ...APPENDIX C PART LISTS ILLUSTRATIONS H325 IAE Rev 004 kortho QiC i series C 33...
Page 160: ...APPENDIX C PART LISTS ILLUSTRATIONS kortho QiC i series H325 IAE Rev 004 C 34...
Page 163: ...APPENDIX D CONNECTIONS H325 IAE Rev 004 kortho QiC i series D 3 X3 Schematic diagram input...
Page 164: ...APPENDIX D CONNECTIONS kortho QiC i series H325 IAE Rev 004 D 4 X3 Schematic diagram output...
Page 165: ...APPENDIX D CONNECTIONS H325 IAE Rev 004 kortho QiC i series D 5 X3 Circuit diagram input...
Page 166: ...APPENDIX D CONNECTIONS kortho QiC i series H325 IAE Rev 004 D 6 X3 Circuit diagram output...
Page 181: ...H325 IAE Rev 004 kortho QiC i series F 1 Appendix F Quick reference...
Page 182: ...APPENDIX F QUICK REFERENCE Kortho QiC i series H325 IAE Rev 004 F 2...
Page 186: ...bv korthofah P O box 3040 2220 CA Katwijk The Netherlands...