![Kortho qic i series User Manual Download Page 31](http://html1.mh-extra.com/html/kortho/qic-i-series/qic-i-series_user-manual_1999038031.webp)
H325 IAE
Rev.: 004
kortho
QiC i-series
4-1
4 SAFETY
This product is designed to conform to all applicable directives, and their relevant harmonized standards, of
the European Council.
4.1 General
This chapter gives an overview of all safety notes mentioned in this manual.
4.1.1 Warning messages
Turn off power before performing maintenance tasks.
When removing covers all air and mains power should be disconnected.
The mains power and air supply must be disconnected when replacing the printhead.
4.1.2 Caution messages
Make sure the interface cable is no longer than 30m. Using a cable longer than 30m can cause EMC
interference.
Do not place any your fingers in the opening in the main plate of the coding unit once the magazine
has been removed. This as there is a small change one cuts oneself on sharp edges on parts inside the
coding unit and there is a very small change one becomes trapped due to moving parts inside the
coding unit.
Be careful when touching / exchanging the printhead. The printhead could be very warm and has some
sharp edges on which one can cut oneself.
Do not use an extension cable for connecting the USB thumbdrive to the control unit, but place the
USB thumbdrive directly in the control unit. Using an extension cable can cause EMC interference.
Always follow the Safety guidelines presented in the SDS of the cleaning solution used.
If the print head resistance is set incorrectly the print head can be damaged resulting in a poor print
quality or no print at all.
These settings will be set during installation; only a trained engineer should change them.
If the label is offset too much one could lose parts of the print. To prevent the most common issues,
the system will perform a check on the Y-offset.
When a new label is loaded: the system will check whether the new label will be completely
printed with current Y-offset. If not the Y-offset will be reset to 0.
When the Y-offset is changed: the system will check whether the current label will be completely
printed with the new Y-offset. If not the system will show a warning telling the Y-offset value is
too high.
If not enough heat is applied to the ribbon, the pigment that makes up the printed label may not adhere
correctly to the product. If too much heat is applied to the ribbon it may not adhere correctly or
potentially the print head could be damaged.
Always use the lowest density setting possible, this as the lifetime of the printhead will be influenced
by the density setting.
Summary of Contents for qic i series
Page 1: ...MANUAL QiC i series Thermal Transfer Printer Edition H325 IAE Rev 004 English kortho...
Page 14: ...INTRODUCTION kortho QiC i series H325 IAE Rev 004 1 6...
Page 30: ...PRINT PROCESS DESCRIPTION kortho QiC i series H325 IAE Rev 004 3 10...
Page 38: ......
Page 42: ...TRANSPORT STORAGE kortho QiC i series H325 IAE Rev 004 5 4...
Page 110: ...MAINTENANCE kortho QiC i series H325 IAE Rev 004 10 6...
Page 120: ...APPENDIX A SPECIFICATIONS kortho QiC i series H325 IAE Rev 004 A 4...
Page 133: ...APPENDIX C PART LISTS ILLUSTRATIONS H325 IAE Rev 004 kortho QiC i series C 7 Magazine QiC 30i...
Page 159: ...APPENDIX C PART LISTS ILLUSTRATIONS H325 IAE Rev 004 kortho QiC i series C 33...
Page 160: ...APPENDIX C PART LISTS ILLUSTRATIONS kortho QiC i series H325 IAE Rev 004 C 34...
Page 163: ...APPENDIX D CONNECTIONS H325 IAE Rev 004 kortho QiC i series D 3 X3 Schematic diagram input...
Page 164: ...APPENDIX D CONNECTIONS kortho QiC i series H325 IAE Rev 004 D 4 X3 Schematic diagram output...
Page 165: ...APPENDIX D CONNECTIONS H325 IAE Rev 004 kortho QiC i series D 5 X3 Circuit diagram input...
Page 166: ...APPENDIX D CONNECTIONS kortho QiC i series H325 IAE Rev 004 D 6 X3 Circuit diagram output...
Page 181: ...H325 IAE Rev 004 kortho QiC i series F 1 Appendix F Quick reference...
Page 182: ...APPENDIX F QUICK REFERENCE Kortho QiC i series H325 IAE Rev 004 F 2...
Page 186: ...bv korthofah P O box 3040 2220 CA Katwijk The Netherlands...