2.7.
Standards and Certifications
The COMe-mAL10 complies with the following standards and certifications. For more information, contact Kontron
Support.
Emission
(EMC)
EN55022: Class B
Information technology equipment, - Radio disturbance characteristics- Limits and methods
of measurement
IEC /EN 61000-6-3
Electromagnetic compatibility (EMC)- Part 6-3:Generic standard – Emission standard for
residential commercial and light industrial environments
IEC/ EN 61000-3-2
Harmonic current emissions
IEC / EN 61000-3-3
Voltage changes, voltage fluctuations and flicker
Immunity
(EMI)
IEC / EN 61000-6-2
Electromagnetic compatibility (EMC) – Part 6-2: Generic standards - Immunity for industrial
environments
Includes the following tests:
IEC / EN 61000-4-2 - Electrostatic discharge immunity (ESD)
IEC / EN 61000-4-3 – Radiated radio frequency electromagnetic field immunity
IEC / EN 61000-4-4 - Electrical fast transient/burst immunity
IEC / EN 61000-4-5 - Surge immunity test
IEC / EN 61000-4-6 - Immunity to conducted disturbances
IEC / EN 61000-4-8 - Power frequency magnetic field Immunity
IEC / EN 61000-4-11 - Voltage dips, short interruptions, and voltage variations immunity
Safety
EN 62368-1
Safety for audio/video and information technology equipment
UL 60950-1 / CSA 60950-1
Information Technology Equipment Including Electrical Business Equipment
NWGQ2.E304278
NWGQ8.E304278
Shock
IEC / EN 60068-2-27
Non-operating shock test – (half-sinusoidal, 11 ms, 15 g)
Vibration
IEC / EN 60068-2-6
Non-operating vibration – (sinusoidal, 10 Hz – 4000 Hz, +/- 0.15 mm, 2 g)
Theoretical
MTBF
System MTBF (hour) = 792647h @ 40°C for COMe-mAL10 N3350 4G
(Reliability report article number: 34008-0400-11-2)
System MTBF (hour) = 702799h @ 40°C for COMe-mAL10 E2 E3950 8E/32S
(Reliability report article number: 34009-0832-16-7)
(RoHS2)
2011/65/EU
Compliant with the directive on the restriction of the use of certain hazardous substances in
electrical and electronic equipment.