Function
1
When each section is operated individually
Attachment: 60L/min
High-Flow attachment: 100L/min
2
When standard attachment and high flow attachment are operated at the same time
1:9=attachment: High-Flow
Operation
1
When each section is operated individually
•
Attachment spool (1) and High-Flow spool (3) stroke fully and individually, therefore they keep demand flow rate in-
dividually.
Attachment: 60L/min
High-Flow: 100L/min
2
When attachment and High-Flow are operated at the same time.
•
High-Flow attachment
PPC
pressure passes through passage
A
, is sent to retainer (2) and makes retainer (2) stroke
to the left.
•
When this happens, attachment spool (1) can stroke by half.
•
As a result, flow rate of attachment and High-Flow are divided as below expression.
Attachment: High-Flow= 1:9
•
Therefore flow rate of high flow is kept.
A
RKS00711
Attachment section
High-flow section
1
3
2
STRUCTURE AND FUNCTION
CLSS
Summary of Contents for SK714-5
Page 1: ...WEBM005500 ...
Page 2: ......
Page 3: ...SK714 5 SK815 5 SK815 5 turbo WEBM005500 00 1 ...
Page 18: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 38: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 83: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 104: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 108: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 112: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 118: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 126: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 172: ......
Page 174: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 253: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 256: ......
Page 257: ......
Page 258: ...2003 ...