10-46
SK714-5 SK815-5 SK815-5 turbo
3.2 SELF LEVELING FUNCTION
Function
•
When the only lever of the lift arm raise is operated, the lift arm raise and the bucket dump are worked.
When this happens, the work equipment can raise with constant bucket bottom angle. (Only the lift arm raise)..
Operation
When the lift arm raise is operated individually.
•
The lift arm spool (1) strokes fully and the bucket spool strokes by half.
•
When this happens, notch (
a
) doesn’t open, so all flow rate from pump supplies to the lift arm raise.
•
The lift arm raise
PPC
pressure is sent by passage
E
.
Then the leveling circulating valve strokes fully.
•
Return flow rate from the lift arm cylinder passes through passage
A
.
Then it is divided to passage
B
and
C
, by the leveling circulating valve (3).
•
When this happens, the flow divider (5) is operated as
P1=P2
, so flow rate (
Q1
,
Q2
) is divided to
B
and
C
in prportion
to the area of opening of notch (
b
) and (
c
) as below expression.
Q1:Q2
= notch (
b
):notch (
C
)
•
Q1
passes through the check valve (6) and then supplies to the bucket cylinder.
RKS00720
P2
P1
Q1
Q2
5
6
2
1
3
4
d
F
b
a
D
c
C
B
E
A
STRUCTURE AND FUNCTION
CLSS
Summary of Contents for SK714-5
Page 1: ...WEBM005500 ...
Page 2: ......
Page 3: ...SK714 5 SK815 5 SK815 5 turbo WEBM005500 00 1 ...
Page 18: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 38: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 83: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 104: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 108: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 112: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 118: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 126: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 172: ......
Page 174: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 253: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 256: ......
Page 257: ......
Page 258: ...2003 ...