40-14
SK714-5 SK815- SK815-5 turbo5
R.H. PPC VALVE
Unit: mm
N°
Check item
Criteria
Remedy
Standard size
Repair limit
Replace
springs.
If there are
damage
or
deformation
Free
installed
x
Øe
Installed
length
Installed
load
Free
length
Installed
load
1
Centering spring (for P3 and P4)
42.4x15.5
34
9.8 N
–
9.2 N
2
Centering spring (for P1 and P2)
36.6x15.5
34
17.6 N
–
16.5 N
3
Metering spring (for P3 and P4)
32.7x8.2
25.6
40.8 N
–
39.4 N
4
Metering spring (for P1 and P2)
26.2x8.2
25.3
5.3 N
–
4.3 N
Section A - A
Section B - B
Section C - C
Section D - D
Section E - E
RKS00852
1
3
2
4
112.8
±
14.7 Nm
44.1
±
4.9 Nm
13.2
±
1.5 Nm
39.2
±
4.9 Nm