30-39
SK714-5 SK815-5 SK815-5 turbo
Whit front door
4 - Disconnect the heating system’s supply (12) and return
(13) hoses from the engine and drain any engine cool-
ant from the hoses.
★
Mark the hoses to avoid mixing them during instal-
lation.
5 - Attach the pump (1) to some hoisting tackle and apply a
slight tension to the cables.
6 - Loosen the eight screws (14) and remove the pump (1)
complete with the flange (15).
Pump: 88 kg
7 - Loosen the screws (16) and disconnect the pump (1)
from the flange (15).
RKSA1547
13
12
RKSA0640
1
RKSA0651
1
14
15
16
1
2
REMOVAL AND INSTALLATION
COMPLETE HYDRAULIC PUMP
Summary of Contents for SK714-5
Page 1: ...WEBM005500 ...
Page 2: ......
Page 3: ...SK714 5 SK815 5 SK815 5 turbo WEBM005500 00 1 ...
Page 18: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 38: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 83: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 104: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 108: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 112: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 118: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 126: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 172: ......
Page 174: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 253: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 256: ......
Page 257: ......
Page 258: ...2003 ...