10-23
SK714-5 SK815-5 SK815-5 turbo
2.
Control of discharge amount
•
If swash plate angle
α
becomes larger, the difference between volumes
E
and
F
becomes larger and discharge
amount
Q
increases.
•
Swash plate angle
α
is changed by control piston (5).
•
Control piston (5) moves in a reciprocal movement (
) according to the signal pressure from pilot line (PPC and
AS valves). This straight line movement is transmitted through slider (6) to rocker cam (4), which is supported by the
cylindrical surface to cradle, slides in a rotating movement in direction (
).
•
On this pump, maximum swash plate angle is
±
15.8°..
•
Screw
A
restricts to the maximum stroke of control piston (i.e. maximum displacement of each pump). When screw
A
is tightened, maximum displacement decreases, and when screw
A
is loosened, maximum displacement in-
crease. This screw should be adjusted when the machine doesn’t travel straight or machine maximum speed is little
bit wrong.
•
Screw
B
is the fine adjuster of neutral position of control piston (5). That adjust prevent machine from creep.
RKS00360
3
4
RKS00280
3
6
4
5
RKS00260
A
B
A
A
5
6
4
5
6
4
B
SK714-5
SK815-5 - SK815-5 turbo
STRUCTURE AND FUNCTION
HYDRAULIC PUMP
Summary of Contents for SK714-5
Page 1: ...WEBM005500 ...
Page 2: ......
Page 3: ...SK714 5 SK815 5 SK815 5 turbo WEBM005500 00 1 ...
Page 18: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 38: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 83: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 104: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 108: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 112: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 118: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 126: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 172: ......
Page 174: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 253: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 256: ......
Page 257: ......
Page 258: ...2003 ...