50
⑵
Input Azimuth and press OK key.
Input angle
value
+
OK
Set Azimuth
HAR
:
5
OK
⑶
Sight at backsight point and press YES.
OK
Set Azimuth
Sight BS point
HAR
:
120°00′00″
NO YES
Record BS data
⑷
Finish azimuth zetting and returns to coordinate
measurement screen.
Coordinate
1. Observation
2. Stn Data
3. Back sight data
10.2.2 Set backsight point by coordinate
You can set backsight azimuth angle by inputting backsight coordinate, the machine calculates azimuth angle by
station point coordinate and backsight coordinate.
Operation Procedure
Key
Display
⑴
In backsight setting menu, choose “2.coord.”.
“2 Coord”
Backsight data
1. Angle
2. Coord.
⑵
After inputting backsight point coordinate NBS,
EBS, ZBS, after each entry press ENT, then
pressOK . To use value in memory, press Readkey.
Input
backsight
point
coordinate
+
ENT
+
OK
Back sight point
NBS
:
1382.450
EBS
:
3455.235
ZBS
:
1234.344
READ OK
⑶
the machine calculates backsight azimuth by
station point coordinate and backsight point
coordinate, screen shows as right.(HAR is the
backsight azimuth)
Set Azimuth
Sight BS Point
HAR
:
40°00′00″
NO YES
Summary of Contents for KTS440 L Series