154
PROCEDURE
Operating Procedure
Operation
Display
⑴
Perform coordinate measurement in the
“MEAS Mode Screen.”
Meas. PC -30
PPM 0
S 1234.789 m
ZA 89°59′54″
HAR 90°01′00″ P2
0SET CRD. S-O REC.
⑵
Press REC in the second page of the “MEAS
Mode Screen.” The “Record Mode Screen” is
displayed.
REC
1. Stn data A:\JOB01
2. back sight data
3. angle data
4. dist data
5. Coord data
6. dist+ coord data
⑶
Select “5. Coord. data” and press ENT, the
measurement results are displayed on lines 2 to 4
(lines indicated by *) of the “Measurement Data
Screen.”
5. Coord data
+
ENT
REC/Coord.
*N 10.364
*E 234.897
*Z 49.098
Pt.
:
POINT2000
REC OBS. OFFS AUTO
⑷
Press REC to record the measurement data
with *.
Enter following data: Point number, code, target
height.
REC
N 10.364
E 234.897
Z 49.098
Pt.
:
POINT2000
Code
:
KOLIDA
SAVE R.HT CODE
⑷
When the self checking is finished, Press SAVE
to record data. System will creates a new point
number by adding “1” on the base of last point
number. user can use this number directly or
create another number by himself
In order to avoid duplicate record , the function
key REC will not show up until a new
measurement happens.
SAVE
REC/Coord.
*N
*E
*Z
Pt.
:
POINT2000
OBS. OFFS AUTO
⑹
Press OBS to measure the coordinates again
in Record Mode.
OBS.
Coordinates
Coord. PC = 0
PPM = 0
Fine “S”
STOP
Summary of Contents for KTS440 L Series