189
19
)
REM setting-out data output command (Gf)
Gf -453.903, 0.000[,SUM]CRLF
a b c
a)
Data identification code
b)
REM setting-out value
c)
REM measured value
1.2 Entering Command
Following commands will be used in receiving data from computer, relative format will be given with commands,
“ ” means space (20H).
·
The input angle and distance value will be displayed in unit set.
·
When entering angle value, the decimal should be behind integer value of angle.
For example: Angle value 359°59′59″ should be entered as 359.5959.
Instrument Computer
·
Sending commands and outputting data
After computer sending input command (1) to instrument, instrument sends a receiving state code (ACK/NAK
communication control)
Computer
Received
06H (ACK)
S
en
d o
u
tp
u
t c
o
m
m
an
d
send 06H (ACK)
after 0.7 second
Well-received
S
en
d n
ex
t c
o
m
m
an
d
bad-received
Send 15H (NAK)
After 0.7 second
Received
15H (NAK)
None
received
Not sent