79
·
It is possible to read in a coordinate data registered in advance.
·
It is possible to record set known point coordinate data or calculated instrument station data in the JOB which has
been selected. For the JOB selection method, see “16.1 JOB Selection”.
·
The target height set here returns to its previously set value after the resection process is completed.
PROCEDURE
Operating Procedure
Operation
Display
⑴
Press RESEC in the third page of Meas
Mode.
Enter coordinate values for the 1 st known point
and press ENT.
·
Stopping an entry in progress: ESC
·
Reading in data: READ
·
Record data: REC
RESEC
Resection
Pt. 1
N 0.000 m 3
E 0.000 m
Z 0.000 m
READ REC OK
⑵
When coordinate entry for the 1 st point has
been completed, press OK. The “2 nd Point
Setting Screen” is displayed.
·
Repeat step 1 to enter the coordinates of all the
known point.
Enter
coordinate
values
Resection
Pt. 2
N 0.000 m 3
E 0.000 m
Z 0.000 m
MEAS READ REC OK
⑶
When all required known points have been
set, press MEAS.
MEAS
Resection
N 4456.343 3
E 4321.890
Z 215.557
Sight Pt. 1
ANG. DIST
⑷
Sight the 1 st known point, press ANG for
angle measurement only. Or press DIST for
angle and distance measurement. When DIST is
selected, the “Observation Start Screen” is
displayed.
DIST
Resection
Dist PC = 0
PPM = 0
Fine “S”
STOP
⑸
When the measurements are completed, of
when STOP is pressed after the measurement
values are displayed during repeat measurement.
·
When ANG has been selected, the distance can
not be displayed.
·
If adopt the result, enter the target height of the
first known point and press YES. Then go to
observe next known point.
·
Discard the result, press NO.
YES
Or NO
Resection Pt. 1
S 353.324 m
ZA 21°34′50″
HAR 78°43′12″
Tgt. h
:
1.560 m
NO YES