148
⑵
Select “1. Stn data” and press ENT (or press
numeric key 4), the present instrument station
data is displayed, there are a total of 4 pages.
Enter the following data items:
Instrument station coordinates
Point number
Code
Instrument height
Operator
Date and time
Weather
Wind
Distance measurement method
Temperature
Air pressure
Atmospheric correction factor
Prism constant correction value
“1. Stn
data”
+
ENT
N0 10.364
E0 234.897
Z0 49.098
Pt.
:
POINT2000
Inst. h
:
1.65 m ↓
SAVE READ OK
Code ↑
:
Name:
:
↓
SAVE CODE OK
Date
:
2010-08-07
Time
:
10
:
14
:
52
Weat
:
Fine
Wind
:
Calm
Mode
:
Fine [S] ↓
SAVE OK
Temp.
:
20
‵
Press.
:
1013.0 hPa
PPM
:
0
PC
:
-30
SAVE 0PPM OK
⑶
After entering all data, press OK to record the
station data and restore the “Record Mode
Screen.”
OK
1. Stn data A:\JOB01
2. back sight data
3. angle data
4. dist data
5. Coord data
6. dist+ coord data
·
Movement of the cursor between items
:
▲ ▼
·
Entry rules
:
Read in coordinate
:
READ
Pt.
:
14 numerals and letters
Code: 16 numerals and letters
Read in code
:
CODE
Time
:
pm 3
:
33
:
37 enter 153337
Date
:
Year 2010 month 8 day 7 enter 20100807
·
Setting methods and content
:
Weather
:
Press
to select (clear, cloudy, light rain, rain, snow)
Wind
:
Press
to select (calm, gentle, light, strong, very strong)
Summary of Contents for KTS440 L Series
Page 9: ...9 3 NOMENCLATURE ...
Page 10: ...10 ...