⑶
Press YES, the last target measured becomes
the new starting position. Refer to “13.1.1
Measuring the Distance Between Multiple
Targets”, perform missing line measurement of
the next target point.
YES
MLM
S 15.483 m
ZA 70°24′18″
HAR 135°31′28″
MLM MOVE S/% OBS
14. REM MEASUREMENT
·
An REM measurement is a function used to measure the height to a point where a target can not be directly
installed, for example a power cable, bridge, etc.
·
The height of the target is calculated using the following formula.
Ht = h1 + h2
h2 = Sinθz1 × Ctgθz2 – Scosθz1
·
When an REM measurement is performed, the initial measurement is performed after 0.7 seconds and later
measurements are performed at 0.5 second intervals no matter which distance measurement method is selected.
·
In advance allocate the function keys to display REM. For the allocation method, see “20. Key Function
Allocation.”
·
It is also possible to perform REM measurement when “5. REM” is pressed under the Menu Mode.