58
·
Select setting-out measurement mode:
Each time press SHV, setting-out measurement mode changes:
SD → HD → VD → COORD → REM
SD: slope distance setting-out measurement.
HD: Horizontal distance setting-out measurement.
VD: height difference setting-out measurement (the height difference between the instrument height mark
and the center point of prism)
COORD: coordinate setting-out measurement (refer to 11.3 Coordinate Setting-Out Measurement)
REM: Remote setting-out measurement (refer to 11.2 REM setting-out measurement)
11.2 REM Setting-Out Measurement
·
To find a point where a target can not be directly installed, perform REM setting-out measurement.
PROCEDURE
Operating Procedure
Operation
Display
⑴
Place a prism directly below or directly
above the point to be found, then use a
measuring tape to measure the prism height
(height from the surveying point to the center
of prism). Sight the prism, press SD
in MEAS mode.
SD
Dist.
Dist PC = 0
PPM = 0
Fine “S”
STOP
⑵
The measurement result is displayed (If in
repetition mode, press STOP).
S: the slope distance to prism
ZA: the vertical angle to prism
HAR: the horizontal angle to prism
Meas
.
PC -30
PPM 0
3
S 18.678 m
ZA 89°59′54″
HAR 90°01′00″
P1
SD SHV S-O EDM
⑶
Press S-O from the second page of MEAS
mode.
S-O
Set-out
1. Observation
2. Set-out
3. Stn data
4. Backsight data
5. EDM
Summary of Contents for KTS440 L Series
Page 9: ...9 3 NOMENCLATURE ...
Page 10: ...10 ...