4-8
Applied Operation
PAD-L
Output voltage control (II) with external resistor (continued)
C
0
1
2
–
–S
+S
+
3
4
5
6
7
8
9
10
0
≤
R2
≤
∞
(infinitive)
a, b:
Constant (depend on model)
Eref: Reference voltage 0-10 V
(Set with the knob on the panel,
0 V at fully CCW,
10 V at fully CW)
R2
Remove the shorting bar
Control terminals
Output terminals
2-core shielded wire
or twisted-pair wire
Output voltage Eo
≈
b
a + R2
x Eref
[V]
Fig, 4-5
Connections for output voltage control (II) with external resistor
Table 4-1
Constant (depend on model)
Type III
PAD
16-100L
PAD
35-50L
PAD
35-60L
PAD
60-35L
PAD
110-20L
PAD
250-8L
Type IV
-
PAD
35-100L
-
PAD
60-60L
PAD
110-30L
PAD
250-15L
Type V
-
PAD
35-200L
-
PAD
60-120L
PAD
110-60L
-
a [k
Ω
]
3.3
3.4
3.4
5
9.8
9.9
b [k
Ω
]
5.2
12
12
30
108
248
Summary of Contents for PAD-L III Series
Page 4: ...II PAD L...
Page 16: ...P 6 Preface PAD L...
Page 40: ...2 12 Precautions and Preparations for Use PAD L...
Page 86: ...4 34 Applied Operation PAD L...
Page 98: ...5 12 Names and Functions of Controls PAD L...
Page 130: ...7 14 Specifications PAD L...