PAD-L
Specifications
7-3
Type III
PAD
16-100L
PAD
35-50L
PAD
35-60L
PAD
60-35L
PAD
110-20L
PAD
250-8L
Range of operation temperature and humidity
0 to 40 ℃ / 10 to 90 %RH (no dew condensation allowed)
Range of storage temperature and humidity
-10 to 60℃ / 0 to 70 %RH (no dew condensation allowed)
Cooling system
Forced air cooling with fan
Output polarity
Positive or negative grounding possible
Isolation voltage
±250 V
±250 V
±250 V
±250 V
±250 V
±500 V
Insulation resistance
Across chassis and input terminals
500VDC, 30MΩmin.
Across chassis and output terminals
500VDC, 20MΩmin.
Withstanding voltage
Across input terminals and output terminals
Across input terminals and chassis
Meter display
Voltmeter Full scale, Class 2.5 (JIS)
16 V
35 V
35 V
60 V
110 V
250 V
Ammeter Full scale, Class 2.5 (JIS)
110 A
60 A
60 A
35 A
22 A
8 A
Remote control
Output voltage/control voltage ratio
16 V /
approx. 10 V
35 V /
approx. 10 V
35 V /
approx. 10 V
60 V /
approx. 10 V
110 V /
approx. 10 V
250 V /
approx. 10 V
Output voltage/control resistance ratio
16 V /
approx. 10kΩ
35 V /
approx. 10kΩ
35 V /
approx. 10kΩ
60 V /
approx. 10kΩ
110 V /
approx. 10kΩ
250 V /
approx. 10kΩ
Output current/control voltage ratio
100 A /
approx. 0.3 V
50 A /
approx. 0.5 V
60 A /
approx. 0.5 V
35 A /
approx. 1.16V
20 A /
approx. 1.0 V
8 A /
approx. 0.8 V
Output current/control resistance ratio
100 A /
approx. 550Ω
50 A /
approx. 1kΩ
60 A /
approx. 1kΩ
35 A /
approx. 1kΩ
20 A /
approx. 1kΩ
8 A /
approx. 1kΩ
Remote sensing
Possible (compensation one way approx. 1.2 V max.)
Master-slave-control parallel operation
Possible
Master-slave-control series operation
Possible
Protective circuit
Operation
POWER switch is turned off.
Trip temperature of thermal protector
100℃/120℃
100 ℃
100 ℃
100 ℃
100 ℃
100 ℃
Voltage setting range
(standard value)
6 to 18 V
6 to 38 V
6 to 38 V
7 to 66 V
20 to 129 V
50 to 280 V
Trigger pulse width
(standard value)
At 200 VAC source
At 100 VAC source
50 A
50 A
60 A
50 A
50 A
50 A
Output fuse rating
100 A
50 A
60 A
40 A
20 A
10 A
Weight
Approx. 63 kg Approx. 58 kg Approx. 61 kg Approx. 62 kg Approx. 60 kg Approx. 60 kg
Dimensions
See dimensional drawings.
Accessory
Operation manual
1 copy
For 200 V
1 piece (30 A)
For 100 V
1 piece (50 A) 1 piece (50 A) 1 piece (60 A) 1 piece (50 A) 1 piece (50 A) 1 piece (50 A)
Power cord
1 piece, 3-core cabtyre cable for 200 VAC input (3.5 mm
2
, approx. 3 m)
Voltage check chip
2 pieces
Guard cap (with one hexagon wrench)
1 piece
2 pieces
2 pieces
2 pieces
2 pieces
2 pieces
1 piece
*5: Mounted on the unit.
Output terminal cover
(with four mounting screws ) *5
Over voltage
protection (OVP)
Input fuse rating
Input fuse (spare)
50 ms
30 A
Should withstand 1500 VAC, 1 min. with no abnormalities