1-8
Setup
PAD-L
Input power voltage changing procedure (continued)
3.
Change the connections of the input terminals of the main power
transformer shown in Fig. 1-3 to the condition shown in Fig. 1-4.
The transformer's input terminals are either A or B, depending on the model.
Main power transformer
Input terminals
Input fuse
A
B
Fig. 1-3
TYPE III model interiors
Main power transformer
Input power voltage: 200V
(Series connection)
Input power voltage: 100V
(Parallel connection)
BLK
GRA x2
WHT x2
WHT/BLK
BLK
GRA x2
WHT x2
WHT/BLK
AWG26
AWG10
100V
0V
100V
0V
CR snubber
Varistor
Main power transformer
AWG26
AWG10
100V
0V
100V
0V
CR snubber
Varistor
M4
M4
Fig. 1-4
Connections involving the input terminals of the main
power transformer