5-10
Names and Functions of Controls
PAD-L
Rear panel (continued)
21 Exhaust ports
This port uses a fan to exhaust heated air from inside. Keep sufficient space around
the unit for good ventilation.
22 Control terminal board
This is the terminal board used for applied operations such as remote control.
In general, connect terminals 0 and 1, terminals 3 and 4, and terminals 5 and 6 using
the shorting bars.
Terminal board screw size: M3
WARNING
•
Incorrect handling may cause electric shock. For details, see
Chapter 4 "Applied Operation".
23 Output terminals
Output is taken from these terminals. The size of the terminals varies by model, as
follows:
• TYPE III models:
M10 bolt
• TYPE IV models:
M10 bolt (PAD250-15L: M5 screw)
• TYPE V models:
M12 bolt (PAD110-60L: M6 screw)
WARNING
•
To avoid electric shock, always turn off the POWER switch
whenever it is necessary to touch the terminals.
24 Sensing terminals
This is used for the remote sensing function.
It is indicated as SAMPLING or +S and -S on the panel, depending on the model.
These terminals are referred to as sensing terminals in this Operation Manual.
For more information on their use, see 4.1 "Remote sensing".
WARNING
•
To avoid electric shock, always turn off the POWER switch
whenever it is necessary to touch the terminals.
CAUTION
•
Do not connect the load directly to the sensing terminals.