Remote Interface Reference
4
Keysight E3633A and E3634A User’s Guide
111
Using the APPLy Command
The
APPLy
command provides the most straightforward method to program the
power supply over the remote interface. You can select the output voltage and
current in one command.
APPLy {<voltage>| DEF|MIN|MAX}[,{<current>| DEF|MIN|MAX}]
This command is combination of
VOLTage
and
CURRent
commands. As long as
the newly programmed values are within the presently selected range, the
output voltage and current are changed as soon as the command is executed.
The
APPLy
command changes the power supply’s output to the newly
programmed values only if the programmed values are valid within the
presently selected range. An execution error will occur if the programmed
values are not valid within the selected range.
You can substitute “
MINimum
”, “
MAXimum
”, or “
DEFault
’’ in place of a specific
value for the voltage and current parameters.
MIN
selects the lowest values of
“0” volts and “0” amps.
MAX
selects the highest values allowed for the selected
range.
The default values of voltage and current are “0” volts and “20”
[1]
or “7”
[2]
amps
regardless of the presently selected range. For more details of parameters, see
for the Keysight E3633A model and
for the Keysight
E3634A model.
If you specify only one parameter of the
APPLy
command, the power supply
regards it as voltage setting value.
[1] For Keysight E3633A Model
[2] For Keysight E3634A Model
Summary of Contents for E3633A
Page 1: ...Keysight E3633A and E3634A DC Power Supplies User s Guide ...
Page 10: ...10 Keysight E3633A and E3634A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 18: ...18 Keysight E3633A and E3634A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 20: ...20 Keysight E3633A and E3634A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 133: ...Remote Interface Reference 4 Keysight E3633A and E3634A User s Guide 133 SCPI Status System ...