Front-Panel Operation
3
Keysight E3633A and E3634A User’s Guide
53
Constant Current Operation
To set up the power supply for constant current (CC) operation, proceed as
follows.
– Front-panel operation:
1 Connect a load to the output terminals.
With power-off, connect a load to the (+) and (-) output terminals.
2 Turn on the power supply
The power supply will go into the
power-on / reset
state; the output is
disabled (the
OFF
annunciator turns on); the 8V/20A
[1]
or 25V/7A
[2]
range
is selected (the
8V
or
25V
annunciator turns on); and the knob is
selected for
voltage
control.
To operate the power supply in the 20V/10A
range, press
key before proceeding to the next step. The
20V
or
50V
annunciator turns on.
3 Set the display to the limit mode.
Notice that the
Limit
annunciator blinks, indicating that the display is in the
limit mode. When the display is in the limit mode, you can see the voltage
and current limit values of the selected supply.
[1] For Keysight E3633A Model
[2] For Keysight E3634A Model
NOTE
In
constant current
mode, the current values between the meter mode and limit
mode are the same, but the voltage values are not. Moreover, if the display is in
the meter mode, you cannot see the change of voltage limit value when
adjusting the knob. We recommend that you should set the display to “limit”
mode to see the change of voltage limit value in the constant current mode
whenever adjusting the knob.
Summary of Contents for E3633A
Page 1: ...Keysight E3633A and E3634A DC Power Supplies User s Guide ...
Page 10: ...10 Keysight E3633A and E3634A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 18: ...18 Keysight E3633A and E3634A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 20: ...20 Keysight E3633A and E3634A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 133: ...Remote Interface Reference 4 Keysight E3633A and E3634A User s Guide 133 SCPI Status System ...