8
Specifications
200
Keysight E3633A and E3634A User’s Guide
Supplemental Characteristics
Remote sensing capability
Temperature coefficient, ±(% of offset)
Maximum change in output/readback per °C after a 30-minute warm-up
Table 8-2
Supplemental Characteristics
Parameter
Keysight E3633A
Keysight E3634A
Output Programming Range
(maximum programmable values)
Low Range
0 to +8.24 V/
0 to 20.6 A
0 to +25.75 V/
0 to 7.21 A
High Range
0 to +20.6 V/
0 to 10.3 A
0 to +51.5V/
0 to 4.12 A
OVP
1 V to 22 V
1 V to 55 V
Voltage Programming Speed:
Maximum time required for output
voltage to settle within 1% of its total
excursion (for resistive load). Excludes
command processing time.
OCP
0 A to 22 A
0 A to 7.5 A
Full Load
No Load
Full Load
No Load
Up
95 msec
45 msec
80 msec
100 msec
Down
30 msec
450 msec 30 msec
450 msec
Voltage drop
Up to 0.7 V per each lead
Load regulation
Add 5 mV to spec for each 1-volt change in the + output lead due to load
current changes
Load Voltage
Subtract voltage drop in load leads from specified output voltage rating.
Voltage
0.01% + 3 mV
Current
0.02% + 3 mA
Summary of Contents for E3633A
Page 1: ...Keysight E3633A and E3634A DC Power Supplies User s Guide ...
Page 10: ...10 Keysight E3633A and E3634A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 18: ...18 Keysight E3633A and E3634A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 20: ...20 Keysight E3633A and E3634A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 133: ...Remote Interface Reference 4 Keysight E3633A and E3634A User s Guide 133 SCPI Status System ...