Remote Interface Reference
4
Keysight E3633A and E3634A User’s Guide
127
*TST?
This query performs a
complete
self-test of the power supply. Returns “0” if
the self-test passes or “1” or any non-zero value if it fails. If the self-test fails,
an error message is also generated with additional information on why the test
failed.
*SAV {1|2|3}
This command stores the present state of the power supply to the specified
location in
non-volatile
memory. Three memory locations (numbered 1, 2 and
3) are available to store operating states of the power supply. The state
storage feature “remembers” the states or values of the following commands:
CURR, CURR:STEP, CURR:TRIG, CURR:PROT, CURR:PROT:STAT, DISP, OUTP,
OUTP:REL, TRIG:DEL, TRIG:SOUR, VOLT, VOLT:STEP, VOLT:TRIG,
VOLT:PROT, VOLT:PROT:STAT,
and
VOLT:RANG
To recall a stored state, you must use the same memory location used
previously to store the state.
*RCL {1|2|3}
This command recalls a previously stored state. To recall a stored state, you
must use the same memory location used previously to store the state.
NOTE
DISP {OFF|ON}
can be stored and recalled in remote interface mode only. Going
to local mode automatically sets the display state to ON.
Summary of Contents for E3633A
Page 1: ...Keysight E3633A and E3634A DC Power Supplies User s Guide ...
Page 10: ...10 Keysight E3633A and E3634A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 18: ...18 Keysight E3633A and E3634A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 20: ...20 Keysight E3633A and E3634A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 133: ...Remote Interface Reference 4 Keysight E3633A and E3634A User s Guide 133 SCPI Status System ...