4-Port System
1. Connect the VNA extender waveguide Ports 1 and 2 together and Ports 3 and 4
together.
2. Select Preset.
3. Set the power level to +20 dBm
1
.
4. Ensure that the following four traces are each setup in a display window (turn on
"Statistics" for each trace):
a. S12 - Trace Uncorrected Thru
b. S21 - Trace Uncorrected Thru
c. S34 - Trace Uncorrected Thru
d. S43 - Trace Uncorrected Thru
5. Normalize the S12, S21, S34 and S43 traces.
6. Set IF BW to 10 Hz.
7. Separate the VNA extenders and connect a flush short (or load) from the cal kit to
the waveguide test port of each extender. (Note that dynamic range is best
measured with loads, but shorts can be used).
8. Set the scale reference level to -100 dB for each window.
9. Verify the mean value is ≥ -100 dB for each trace.
10. See
Figure 26
below for a display example.
Figure 26
4-Port Dynamic Range Check with Statistics
1. En20 dBm in the VNA menu will result in approxi13 dBm of output at the waveguide test port.
N5252-90002 User's Guide
35
Summary of Contents for N5252A
Page 1: ...User s Guide Keysight Technologies N5252A and N5253E E Band Vector Network Analyzer Systems ...
Page 5: ...Introduction N5252 90002 User s Guide 5 ...
Page 16: ...System Setup 16 N5252 90002 User s Guide ...
Page 31: ...Figure 22 Installation Calibration Steps N5252 90002 User s Guide 31 ...
Page 33: ...Figure 23 2 Port Receiver Check Figure 24 4 Port Receiver Check N5252 90002 User s Guide 33 ...
Page 48: ...Troubleshooting Maintenance and Support 48 N5252 90002 User s Guide ...
Page 55: ...Safety and Regulatory Information N5252 90002 User s Guide 55 ...