Figure 11
Port 3 Configuration
Port 3 Configuration - Option 400 Only
4-Port Setup
M9374A Module #3 with VDI Extender #3
Cable
Type
1
RF/LO
IF
M9374A
Module #3
VDI
Extender #3
Port 1
to
Port 2
RF/R
M
Figure
Reference
Table 9
Port 3 Configuration Cable Connections
A
B
to
1. Install the two cables between M9374A Module #3 and VDI Extender #3. See
Table 9
and
Figure 11
.
2. If not already installed, install two 50 Ω loads to LO In and LO Out on M9374A Module #3. If not
already installed, install a reference jumper and a trigger jumper on Modules #2 and #3. See
Figure 11
.
3. Confirm Port 2 LO-O is connected to Port 3 LO-I.
4. Connect VDI Extender #3 (LO-O) to VDI Extender #4 (LO-I) with an RF/LO cable. See
Figure 11
.
5. Connect the power cord to VDI Extender #3. See
Figure 11
.
An RF cable up to 5 meters in length can be used for an LO-O to LO-I connection
between extenders. The M9374A LO Out can only support 1.2 meter cable lengths.
A
B
1. RF/LO cables are thicker then the IF cables and are marked RF/LO or IF at the end of the cables.
20
N5252-90002 User's Guide
Summary of Contents for N5252A
Page 1: ...User s Guide Keysight Technologies N5252A and N5253E E Band Vector Network Analyzer Systems ...
Page 5: ...Introduction N5252 90002 User s Guide 5 ...
Page 16: ...System Setup 16 N5252 90002 User s Guide ...
Page 31: ...Figure 22 Installation Calibration Steps N5252 90002 User s Guide 31 ...
Page 33: ...Figure 23 2 Port Receiver Check Figure 24 4 Port Receiver Check N5252 90002 User s Guide 33 ...
Page 48: ...Troubleshooting Maintenance and Support 48 N5252 90002 User s Guide ...
Page 55: ...Safety and Regulatory Information N5252 90002 User s Guide 55 ...