The following figure details the 40W indoor DC/DC converter:
Figure 46 : Isolated 40W DC/DC converter
1.7
Power consumption
The maximum power consumption of each individual module is detailed hereafter:
Module
Power consumption
CPU module (20% load)
1.8W max
WAN module (HSPA, 25% Tx, 75% Rx)
1.7W max
LoRa LOC module (Rx mode)
6.5W max
Four LoRa LOC module (Rx mode)
20W
Four LoRa LOC module (Rx + Tx mode - FDx)
25W
The maximum power consumption per day of the Wirnet iBTS is then the following:
Wirnet iBTS
Power consumption
Wirnet iBTS Compact (1 LoRa LOC Module)
237Wh max
Wirnet iBTS with 2 x LoRa LOC Modules
392Wh max
Wirnet iBTS with 3 x LoRa LOC Modules
547Wh max
Wirnet iBTS with 4 x LoRa LOC Modules
702Wh max
Wirnet iBTS FDx
720Wh max
Note:
the power supply of the Wirnet iBTS must be a limited power source.