iBTS is directly connected to the earthing system of the installation, dysfunction may occur
without additional insulation. In such casing, Kerlink recommends using additional isolated
DC/DC.
The following drawing shows the insulation importance of an additional isolated DC/DC
power supply:
Figure 45 : Required isolation on auxiliary power supply input
An example of 40W isolated DC/DC converter is provided in the chapter 1.6.3
1.6.3
Isolated DC/DC converter 40W
As detailed in paragraph 1.6.2, some specific installation using -48V DC supply require an
isolated DC/DC converter.
The characteristics of a 40W isolated DC/DC converter are detailed in the following table:
Description
Specification
Input Voltage
48V DC typ.
18-75V DC range
Input current at full load
0.93A
Undervoltage Lockout
ON at >18V
OFF at <16V
Remote On/Off
On: Logic High (3.5-12 V) or open circuit
Off: Logic Low (<1.2 V) or short pin 1 to pin 2
0V
-48V
48V
Wirnet iBTS Station
DC/DC
Isolated