Wirnet iBTS
Document title : Installation and
Maintenance Manual
Version : 2.0
Author : SNI
Date : 04/12/2018
Classification
This document is the strict property of Kerlink and shall not be either copied nor sent without express
written authorization of Kerlink
Internal Use
Kerlink m2m technologies reserved rights
Confidential
Kerlink – 1 rue Jacqueline Auriol – 35235 THORIGNÉ-FOUILLARD
Page 211 / 221
Strict confidential
5.
Maintenance of the Wirnet iBTS
5.1
Simple checks
5.1.1
Wirnet iBTS enclosure
Check the robustness of the installation:
-
Screwing of the Wirnet iBTS station on the mounting kit
-
Screwing of the mounting kit (depends on the configuration)
Check the Ingress Protection of the enclosure:
-
No trace of water inside the enclosure
-
Tightening of the cable gland
-
Tightening / screwing of the N connectors
-
Tightening of the pressure stabilizers
-
Tightening / screwing of the blind stops
-
Gasket on the door
5.1.2
User interface
Check the USIM is properly inserted in the USIM connector of the WAN module
Check the LED indicators on the CPU module inside the enclosure:
Connector
LED
Description
LOCAL
Green
Ethernet data activity
LOCAL
Orange
Ethernet Link
PoE/LAN
Green
Ethernet data activity
PoE/LAN
Orange
Ethernet Link
DEBUG
Green
Power status
DEBUG
Orange
Software status/ activity
5.1.3
Cables and antennas
Check tightening and cabling of the antennas:
-
The coaxial cables of LoRa, GNSS (GPS) and LTE antennas are well screwed and
tightened on the Wirnet iBTS N connectors.
-
The coaxial cables of LoRa, GNSS (GPS) and LTE antennas are not deteriorated.
-
The LoRa, GNSS (GPS) and LTE antennas are well screwed and tightened on their
brackets.
-
The antenna brackets are well tightened to the wall or pole.
-
RJ45/PoE cable is not deteriorated.
Check earthing of the installation:
-
An mounting kit earthing cables are connected and not deteriorated.
-
Wirnet iBTS + mounting kit earthing cable is connected and not deteriorated.
-