4-6
Laser Diode Testing
Model 2520 User’s Manual
Table 4-2
Laser diode test commands
Command
Description
:CALCulate[1]:FORMat <format>
:CALCulate[1]:DATA?
:CALCulate[1]:STATe <state>
:CALCulate[1]:KMATh:MBFactor <B>
:CALCulate[1]:KMATh:MMFactor <M>
:CALCulate[1]:KMATh:MUNits “<units>”
:CALCulate2:DATA?
:CALCulate2:STATe <state>
:CALCulate2:KMATh:MBFactor <B>
:CALCulate2:KMATh:MMFactor <M>
:CALCulate2:KMATh:MUNits “<units>”
:CALCulate3:DATA?
:CALCulate3:STATe <state>
:CALCulate3:KMATh:MBFactor <B>
:CALCulate3:KMATh:MMFactor <M>
:CALCulate3:KMATh:MUNits “<units>”
:CALCulate4:DATA?
:CALCulate4:STATe <state>
:FORMat:ELEMents <elements>
:FORMat:ELEMents:CALCulate <elements>
:INIT
:OUTPut[1] <state>
:READ?
:SENSe[1]:VOLTage:RANGe <range>
:SENSe[1]:VOLTage:POLarity <polarity>
:SENSe2:CURRent:RANGe <range>
:SENSe2:CURRent:POLarity <polarity>
:SENSe3:CURRent:RANGe <range>
:SENSe3:CURRent:POLarity <polarity>
Define laser diode math format (MXB[1],
CONDuctance[1]), POWER[1], or RESistance[1]).
1
Request laser diode math reading.
Enable/disable laser diode math (ON or OFF).
Set laser diode MX + B, B (offset) parameter.
Set laser diode MX + B, M (slope) parameter.
Define laser diode MX + B units (1-character ASCII
string).
Request detector #1 math reading.
Enable/disable detector #1 math (ON or OFF).
Set detector #1 MX + B, B (offset) parameter.
Set detector #1 MX + B, M (slope) parameter.
Define detector 1 MX + B units (1-character ASCII string).
Request detector #2 math reading.
Enable/disable detector #2 math (ON or OFF).
Set detector #2 MX + B, B (offset) parameter.
Set detector #2 MX + B, M (slope) parameter.
Define detector 2 MX + B units (1-character ASCII string).
Request delta (detector #1 - detector #2 current reading).
Enable/disable delta measurement (ON or OFF).
Select :READ? data elements (CURRent[1], VOLTage[1],
CURRent2, VOLTage2, CURRent3, VOLTage3, STATus,
or TIME).
2
Select CALC data elements (CALCulate, STATus, or
TIME).
Trigger readings.
Turn all sources ON or OFF.
Trigger and acquire readings.
Set laser diode voltage measure range (5 or 10).
Set laser diode measure polarity (POSitive or NEGative).
Set detector #1 measure range (0.01, 0.02, 0.05, 0.1).
Set detector #1 measure polarity.
Set detector #2 measure range (0.01, 0.02, 0.05, 0.1).
Set detector #2 measure polarity.
1
COND = I
L
/V
L
; RES = V
L
/I
L
; POWER = V
L
* I
L
.
2
CURR1 = I
L
; VOLT1 = V
L
; CURR2 = I
PD1
; VOLT2 = V
B2
; CURR3 = I
PD3
; VOLT3 = V
B2
.
3
5.0A maximum pulse mode only. 1A maximum in DC mode.
4
Settings affected by maximum duty cycle. See
.
Summary of Contents for 2520
Page 250: ...A Specifications ...
Page 254: ...B StatusandErrorMessages ...
Page 262: ...C DataFlow ...
Page 266: ...D IEEE 488BusOverview ...
Page 281: ...E IEEE 488andSCPI ConformanceInformation ...
Page 285: ...F MeasurementConsiderations ...
Page 308: ...G GPIB488 1Protocol ...
Page 312: ...H ExamplePrograms ...
Page 317: ...I ContinuousPulseMode ...