66
Operational Information:
The LEDs on the DCC Utility card and their functions have been explained below:
POWER:
This LED is supposed to be continuously ON. If it flashes, then the DCC block must
be turned OFF and then back ON after 15-20 seconds.
DSP-A, DSP-B, DSP-C, DSP-D:
These LEDs signify that the DSP unit is operational. They
are supposed to be blinking periodically.
10 RX, 10 TX / 100RX, 100TX:
These are supposed to be flashing during data transmission
or reception over local area network (LAN).
CPU:
It is supposed to blink periodically.
M/S (Master/Slave): This LED is supposed to be continuously ON, if the master DCC Utility
card is functional in the DCC Block.
LOCK:
DCC This LED is supposed to be blinking periodically, if DCC is using external clock.
If does not blink periodically, then that signifies there is a problem with the external clock
signal.
HOLD:
This LED is supposed to be continuously ON, if DCC is using its own clock signal.
Summary of Contents for DS200
Page 1: ...11 2010 TECHNICAL REFERENCE AND INSTALLATION GUIDE PBX DS SERIES...
Page 2: ...DS SERIES PBX TECHNICAL REFERENCE AND INSTALLATION GUIDE NOVEMBER 2010...
Page 17: ...DS Series PBX Technical Reference And Installation Guide 7...
Page 69: ...DS Series PBX Technical Reference And Installation Guide 59...
Page 80: ...70...
Page 222: ...11 2010...