12-
The covers are replaced by paying attention to coinciding the cables with the
corresponding cable slots that are on the back of the covers.
13- If SPS200 has been removed in order to facilitate the installation, then it is replaced as
explained in detail later in the guide.
14- The 230 VAC cable is attached to the corresponding input on SPS200. Before plugging
the other end of the cable into the outlet, the statuses of on/off switches and soundness
of fuses must be checked. The mains on/off switch must be off. Keep in mind that the
battery on/off switch must be set to “on” after the mains supply is on and it must be set to
“off” before the mains is shut off. (How to put the system into service is explained in the
last section.)
Two 2A T-type fuses that are required for 230 VAC are present in the drawer-type
compartment next to the 230 VAC input.
XII.1.B. HOW TO SET UP THE CABINET-TYPE DS200
SYSTEM
1- The cabinet is taken to a location that complies with the requirements defined in the
preparation step.
2- The wheels are locked by pressing their latches, so that it is ensured the exchange would
not move.
3- The front cover is opened and the rack stopper screws, which have been attached to the
slots to prevent the racks to slide, are removed.
Summary of Contents for DS200
Page 1: ...11 2010 TECHNICAL REFERENCE AND INSTALLATION GUIDE PBX DS SERIES...
Page 2: ...DS SERIES PBX TECHNICAL REFERENCE AND INSTALLATION GUIDE NOVEMBER 2010...
Page 17: ...DS Series PBX Technical Reference And Installation Guide 7...
Page 69: ...DS Series PBX Technical Reference And Installation Guide 59...
Page 80: ...70...
Page 222: ...11 2010...