Property Network Diagram
Minimum Equipment Requirements & Recommendations
ENCODER
WITH USB
CONNECTION
KEY CONTROL
CAT 5 CABLE
NETWORK
PRINTER
CAT 5
CABLE
RS232 CABLE
CLIENT
USB
CAT 5 CABLE
CAT 5 CABLE
ENCODER
WITH TCP/IP CONNECTION
ENCODER
WITH
SERIAL
CONNECTION
SAFLOK
SERVER
ENCODER
WITH TCP/IP CONNECTION
SWITCH
(This diagram assumes that an Ethernet 10/100 multi-port hub is installed on the network.)
SAFLOK
™
Server
• Operating system: Windows XP Professional or Windows Server
2003 (Windows Server 2003 is required if over ten [10] workstations);
appropriate server and client licensing is required
• Minimum hardware specifications: Multi-core, 2 GHz or greater
CPU / 4GB or greater RAM / 100GB available hard drive space
• Virtual Machine environments are supported with the following
minimum resource allocation: Multi-core, 2 GHz or greater CPU
allocation / 4GB or greater RAM / 100GB available hard drive space
• If more than two (2) workstations are to be used with
Saflok, an Ethernet network hub or switch is required
• If connecting an encoder and/or handheld LPI device
directly to server, at least one (1) USB port must be
available for encoder connection and at least one (1)
dedicated Serial port for handheld LPI connection
• If including a Serial property management system
(PMS) interface, at least one (1) dedicated Serial
port must be available. TCP/IP interface support
is also available.
• Internet access is required to enable SAFLOK
remote real-time support via the web
• Anti-virus software is highly recommended
• UPS and surge protection with equipment
warranty are suggested
Client Workstation(s)
• Operating system: Windows XP, Vista, or Windows 7
• Minimum hardware specifications: 1 GHz processor,
1GB of RAM, and 10GB available hard drive space
• If connecting an encoder and/or handheld LPI device
directly to workstation, at least one (1) USB port must
be available for encoder connection and/or at least one
(1) Serial port for handheld LPI connection; encoders can
also utilize a TCP/IP (network) or Serial connection
• Anti-virus software is highly recommended
• UPS and surge protection with equipment
warranty are suggested
Notes:
• All network installations and maintenance are the responsibility
of the individual customer and not SAFLOK.
• Due to the wide performance variability of different manufacturers’
hardware, SAFLOK cannot guarantee software compatibility with
all computers. If you require a list of computers that SAFLOK has
tested and deemed software-compatible, please contact SAFLOK
customer service at 1.800.999.6213.
• The customer is responsible for completing all software updates
(e.g., Windows operating system & anti-virus protection).
• If using a Serial interface with a Virtual Machine, the Virtual
Machine host computer must have an available dedicated Serial
port that can be allocated to the Saflok Server Virtual Machine.
Summary of Contents for Saflok SYSTEM 6000
Page 1: ...REFERENCE MANUAL SYSTEM 6000 ...
Page 2: ...SAFLOK TRAINING AND REFERENCE MANUAL SAFLOK SYSTEM 6000 WINDOWS VERSION 3 ...
Page 4: ...Section 1 Introduction to System 6000 ...
Page 9: ...SECTION 2 System 6000 Installation and Configuration ...
Page 35: ...SECTION 3 Lock and Keycard Features ...
Page 59: ...System 6000 TM Reference Manual_Section 4 Section 4 Lock Operation SAFLOK Page 1 of 16 06_11 ...
Page 75: ...System 6000 TM Reference Manual_Section 5 Section 5 System 6000 Transactions ...
Page 99: ...System 6000 TM Reference Manual_Section 6 Section 6 Diagnostics Error Codes ...