System
6000
TM
Reference
Manual_Section
6
© SAFLOK
Page
23
of
34
06/11
024
PI
Pass
Master:
In
order
to
change
the
valid
pass
numbers,
the
pass
criteria
must
also
be
programmed
in.
Contact
SAFLOK
for
assistance.
025
PI
Pass
Master:
If
the
key’s
pass
criteria
equals
0,
all
the
pass
numbers
must
equal
0.
Contact
SAFLOK
for
assistance.
026
PI
Pass
Master:
If
the
key’s
pass
criteria
equals
1,
all
the
pass
numbers
cannot
equal
0.
Contact
SAFLOK
for
assistance.
PI
Level
Program
Errors
in
Program
Cycle
Code
Description
027
PI
Level
Program:
If
PI
key’s
current
program
group
number
does
not
equal
0,
then
it
must
equal
the
key
type’s
program
group
number.
Contact
SAFLOK
for
assistance.
028
PI
Level
Program:
If
the
key
type’s
program
group
equals
0
(non
‐
operating),
the
PI
key
must
program
in
the
operation.
Contact
SAFLOK
for
assistance.
029
PI
Level
Program:
PI
key
cannot
program
in
the
function
without
programming
in
the
sub
‐
function
and
additional
function
information.
Contact
SAFLOK
for
assistance.
030
PI
Level
Program:
PI
key
function
greater
then
5
is
invalid
or
PI
key
is
not
programming
in
the
function
and
its
function
does
not
equal
key
type’s
function.
Contact
SAFLOK
for
assistance.
031
PI
Level
Program:
PI
key
has
invalid
value
for
the
sub
‐
function
or
additional
function
based
on
the
key’s
function
value.
Contact
SAFLOK
for
assistance.
PI
Key
Master
Errors
in
Program
Cycle
Code
Description
032
PI
Key
Master:
Add/Change/Delete
–
The
PI
key
is
for
a
key
level
with
operation
equals
0
(non
‐
operating)
or
equals
7
(pass)
which
doesn’t
have
individual
keys.
Contact
SAFLOK
for
assistance.
033
PI
Key
Master:
Add/Change/Delete
–
The
PI
key’s
New
Key
Date/Time
fields
have
invalid
values.
Contact
SAFLOK
for
assistance.
034
PI
Key
Master:
Change/Delete
–
The
PI
key
record
number
is
not
in
the
lock
so
it
cannot
change/delete
the
key.
Contact
SAFLOK
for
assistance.
035
PI
Key
Master:
Change/Delete
–
The
PI
key
is
not
programming
or
overriding
the
key’s
New
Date
and
the
key’s
New
Date
doesn’t
match
the
lock’s
key
data.
Contact
SAFLOK
for
assistance.
036
PI
Key
Master:
Add
–
The
PI
key’s
record
number
is
already
in
the
lock
level
so
it
cannot
be
added.
Contact
SAFLOK
for
assistance.
037
PI
Key
Master:
Add/Change
–
The
level
has
a
batch
operation
and
the
PI
key
cannot
add/change
a
Sequence
Number
greater
than
32.
Contact
SAFLOK
for
assistance.
038
PI
Key
Master:
Change/Delete
–
The
PI
key
is
not
programming
or
overriding
the
key’s
Sequence
Number
and
the
key’s
Sequence
Number
does
not
match
the
lock’s
key
data.
Contact
SAFLOK
for
assistance.
Summary of Contents for Saflok SYSTEM 6000
Page 1: ...REFERENCE MANUAL SYSTEM 6000 ...
Page 2: ...SAFLOK TRAINING AND REFERENCE MANUAL SAFLOK SYSTEM 6000 WINDOWS VERSION 3 ...
Page 4: ...Section 1 Introduction to System 6000 ...
Page 9: ...SECTION 2 System 6000 Installation and Configuration ...
Page 35: ...SECTION 3 Lock and Keycard Features ...
Page 59: ...System 6000 TM Reference Manual_Section 4 Section 4 Lock Operation SAFLOK Page 1 of 16 06_11 ...
Page 75: ...System 6000 TM Reference Manual_Section 5 Section 5 System 6000 Transactions ...
Page 99: ...System 6000 TM Reference Manual_Section 6 Section 6 Diagnostics Error Codes ...