System
6000
TM
Reference
Manual_Section
6
© SAFLOK
Page
25
of
34
06/11
PI
Clock
(&
PI
Number)
Errors
in
Program
Cycle
Code
Description
050
PI
Clock:
The
lock’s
DST
information
is
not
programmed
in
and
must
be
before
a
PI
Clock
key
can
be
used.
Contact
SAFLOK
for
assistance.
051
PI
Clock:
The
lock’s
batteries
are
low
and
must
be
changed
before
a
PI
Clock
key
can
be
used
(Clock
time
is
lost
if
batteries
are
disconnected).
Contact
SAFLOK
for
assistance.
052
PI
Clock:
PI
key
cannot
indicate
the
clock
reset
interval,
months
will
be
programmed
in
using
PI
Number/Time
keys.
Contact
SAFLOK
for
assistance.
053
PI
Clock:
PI
key
must
program
both
date
(months,
date,
year)
and
time
(hours,
minutes,
seconds)
together
–
one
or
the
other
is
not
allowed.
Contact
SAFLOK
for
assistance.
054
PI
Clock:
If
programming
in
date
and
time,
PI
key
must
indicate
the
month,
date,
hours
and
minutes
–
data
is
either
all
on
the
PI
key
or
will
all
come
from
PI
Number/Time
keys.
Contact
SAFLOK
for
assistance.
055
PI
Clock:
PI
key
cannot
indicate
the
clock
year
–
will
be
programmed
in
using
PI
Number/Time
keys.
Contact
SAFLOK
for
assistance.
056
PI
Clock:
PI
key
cannot
indicate
the
clock
seconds
–
will
be
programmed
in
using
PI
Number/Time
keys.
Contact
SAFLOK
for
assistance.
057
PI
Clock:
If
DST
observance
is
non
‐
standard,
the
PI
Clock
key’s
year
must
equal
the
DST
change
dates/year
value.
Contact
SAFLOK
for
assistance.
058
PI
Clock
&
PI
Number/Time:
The
month
value
is
invalid
(1
‐
12
only).
Contact
SAFLOK
for
assistance.
059
PI
Clock
&
PI
Number/Time:
The
date
value
in
invalid
(1
‐
31
only
and
also
maximum
based
on
the
month
provided
&
Leap
Years).
Contact
SAFLOK
for
assistance.
060
PI
Clock
&
PI
Number/Time:
The
hour
value
in
invalid
(0
‐
11
only,
noon
equals
0).
Invalid
Key
Field
Values
(type,
function
data,
etc.).
Contact
SAFLOK
for
assistance.
061
PI
Clock
&
PI
Number/Time:
The
minute’s
value
is
invalid
(0
‐
59
only).
Invalid
Key
Field
Values
(type,
function,
data,
etc.).
Contact
SAFLOK
for
assistance.
062
PI
Clock
&
PI
Number/Time:
The
second’s
value
is
invalid
(0
‐
59
only).
Invalid
Key
Field
Values
(type,
function,
data,
etc.).
Contact
SAFLOK
for
assistance.
Summary of Contents for Saflok SYSTEM 6000
Page 1: ...REFERENCE MANUAL SYSTEM 6000 ...
Page 2: ...SAFLOK TRAINING AND REFERENCE MANUAL SAFLOK SYSTEM 6000 WINDOWS VERSION 3 ...
Page 4: ...Section 1 Introduction to System 6000 ...
Page 9: ...SECTION 2 System 6000 Installation and Configuration ...
Page 35: ...SECTION 3 Lock and Keycard Features ...
Page 59: ...System 6000 TM Reference Manual_Section 4 Section 4 Lock Operation SAFLOK Page 1 of 16 06_11 ...
Page 75: ...System 6000 TM Reference Manual_Section 5 Section 5 System 6000 Transactions ...
Page 99: ...System 6000 TM Reference Manual_Section 6 Section 6 Diagnostics Error Codes ...