System
6000
TM
Reference
Manual_Section
6
© SAFLOK
Page
20
of
34
06/11
6.8
Diagnostics
Error
Codes
LPI
Programming
Errors
If
an
error
occurs
when
a
lock
is
being
programmed,
the
LPI
Terminal
will
display
the
following
screen
indicating
an
error
code
on
the
Error
Line:
*
*
*
LPI
ERROR
XXX
*
*
*
Error
Occurred
When
Sending
Key
Level
xx,
Type
yy,
xxxxxxxxxx
LOCK
AND
PROBE
COMMUNICATIONS
HAVE
BEEN
TERMINATED
(PRESS
Any
Key)
The
code
number
indicated
on
the
Error
Line
is
the
same
as
that
used
by
LED
Diagnostics
and
you
can
refer
to
the
codes
in
this
section
for
information
about
the
problem.
For
LPI
Programming
errors,
you
will
need
to
contact
SAFLOK
for
assistance,
and
your
SAFLOK
representative
will
need
this
error
code
information.
Most
Common
Diagnostics
Error
Codes
The
following
error
codes
are
most
likely
to
appear
when
performing
LED
Diagnostics:
Code
Description
113
All
Keys:
The
key
is
not
valid
in
the
current
lock
mode
or
cycle.
If
LED
Diagnostics
is
on,
turn
off.
Lock
is
typically
in
an
invalid
mode.
Refer
to
Section
3,
Invalid
Mode
Indicators
for
additional
information.
This
code
may
also
appear
if
you
use
Standard
or
Display
keys
when
the
PPK
or
SPK
LEDs
are
flashing.
117
Standard,
Special,
PPK
and
SPK
Keys:
the
lock
is
in
shutdown
cycle
because
10
or
more
invalid
keys
were
used.
A
valid
key
must
be
used
to
terminate
shutdown
mode.
122
Standard
Keys:
Lock
is
non
‐
operating
for
this
key
type.
The
key
does
not
belong
to
this
lock.
123
Standard
and
Special
Keys:
Key
is
not
mastered
into
the
lock.
The
key
does
not
belong
to
this
lock.
127
Standard
Keys:
Key
does
not
have
one
of
the
12
valid
Pass
numbers
required
for
the
Pass
function.
128
Standard
and
Special
Keys:
Key
is
an
old
key;
its
new
key
date
is
earlier
than
the
lock’s
key
data.
Replace
the
key
with
a
current
or
new
key.
129
Standard
and
Special
Keys:
Key
is
an
old
key;
its
new
key
time
is
earlier
than
the
lock’s
key
data.
Replace
the
key
with
a
current
or
new
key.
134
Standard
and
Special
Keys:
Key
is
an
old
key:
Key
type
has
limited
sequence
range
(1
‐
15)
but
key’s
sequence
number
is
older
than
the
lock’s
key
data.
Replace
key
with
a
current
or
new
key.
Use
a
re
‐
sequence
key
if
necessary.
Summary of Contents for Saflok SYSTEM 6000
Page 1: ...REFERENCE MANUAL SYSTEM 6000 ...
Page 2: ...SAFLOK TRAINING AND REFERENCE MANUAL SAFLOK SYSTEM 6000 WINDOWS VERSION 3 ...
Page 4: ...Section 1 Introduction to System 6000 ...
Page 9: ...SECTION 2 System 6000 Installation and Configuration ...
Page 35: ...SECTION 3 Lock and Keycard Features ...
Page 59: ...System 6000 TM Reference Manual_Section 4 Section 4 Lock Operation SAFLOK Page 1 of 16 06_11 ...
Page 75: ...System 6000 TM Reference Manual_Section 5 Section 5 System 6000 Transactions ...
Page 99: ...System 6000 TM Reference Manual_Section 6 Section 6 Diagnostics Error Codes ...