System
6000
TM
Reference
Manual_Section
6
© SAFLOK
Page
27
of
34
06/11
PI
Basic
Errors
in
Program
Cycle
continued
Code
Description
120
All
Keys:
Expiration
Date
and
Time
or
New
key
Date
and
Time
contain
invalid
values
for
month,
date,
hours
or
minutes
(example:
25:00,
4/31,
etc.).
Contact
SAFLOK
for
assistance.
121
Standard,
Special,
PPK
and
SPK
Keys:
Key’s
ID
number
equals
0
(invalid).
Contact
SAFLOK
for
assistance.
122
Standard
Keys:
Lock
level
is
non
‐
operating
for
this
key’s
type.
The
key
does
not
belong
to
this
lock.
123
Standard
and
Special
Keys:
Key
is
not
mastered
into
the
lock.
The
key
does
not
belong
to
this
lock.
124
Standard
Keys:
The
lock
level
is
Pass,
but
Pass
Mastering
key
has
not
been
programmed
in
yet
so
key
cannot
be
verified.
Contact
SAFLOK
for
assistance.
125
Standard
Keys:
Lock
was
in
a
dual
key
cycle
awaiting
another
dual
key,
but
this
key
does
not
belong
to
a
level
with
a
dual
key
function.
You
must
use
another
dual
key
after
using
the
first
dual
key.
126
Standard
Keys:
Lock
is
in
Override
Mode
3
and
the
PPK
key
used
prior
to
this
key
did
not
have
the
authorization
to
work
with
a
Standard
key.
You
must
use
a
PPK
key
with
proper
authorization.
127
Standard
Keys:
Key
does
not
have
one
of
the
12
valid
pass
numbers
required
for
the
pass
level.
128
Standard
and
Special
Keys:
Key
is
an
old
key;
its
new
key
date
is
earlier
than
the
lock’s
key
data.
Replace
the
key
with
a
current
or
new
key.
129
Standard
and
Special
Keys:
Key
is
an
old
key;
its
new
key
time
is
earlier
than
the
lock’s
key
data.
Replace
the
key
with
a
current
or
new
key.
130
Standard
Keys:
Key
is
an
invalid
key,
lock
level
is
batch
and
the
key’s
sequence
number
is
invalid
(not
equal
to
1
‐
32).
Contact
SAFLOK
for
assistance.
131
Standard
Keys:
Key
is
an
old
key,
lock
level
is
batch
and
the
key’s
sequence
number
has
already
been
used.
Replace
key
with
an
unused
sequence.
132
Special
Keys:
key
is
an
old
key,
its
new
key
date
and
time
is
earlier
than
the
lock’s
key
data.
Replace
key
with
a
current
or
new
key.
133
Standard
and
Special
Keys:
Key
is
an
old
key,
level
has
unlimited
sequence
range
but
key’s
sequence
number
is
older
than
the
lock’s
key
data.
Replace
key
with
a
current
or
new
key.
Use
a
re
‐
sequence
key
if
necessary.
134
Standard
and
Special
Keys:
Key
is
an
old
key,
level
has
limited
sequence
range
(1
‐
15)
but
key’s
sequence
number
is
older
than
the
lock’s
key
data.
Replace
key
with
a
current
or
new
key.
Use
a
re
‐
sequence
key
if
necessary.
Summary of Contents for Saflok SYSTEM 6000
Page 1: ...REFERENCE MANUAL SYSTEM 6000 ...
Page 2: ...SAFLOK TRAINING AND REFERENCE MANUAL SAFLOK SYSTEM 6000 WINDOWS VERSION 3 ...
Page 4: ...Section 1 Introduction to System 6000 ...
Page 9: ...SECTION 2 System 6000 Installation and Configuration ...
Page 35: ...SECTION 3 Lock and Keycard Features ...
Page 59: ...System 6000 TM Reference Manual_Section 4 Section 4 Lock Operation SAFLOK Page 1 of 16 06_11 ...
Page 75: ...System 6000 TM Reference Manual_Section 5 Section 5 System 6000 Transactions ...
Page 99: ...System 6000 TM Reference Manual_Section 6 Section 6 Diagnostics Error Codes ...