6.2
Special
Function
Light
Indicators
Resequence
Keycard
The
Resequence
keycard
is
used
to
update
the
sequence
number
stored
in
the
lock’s
memory
when
the
number
of
new
keycards
made
but
not
used
in
the
lock
exceeds
the
programmed
sequence
range
for
that
keycard.
When
a
Resequence
keycard
is
used,
the
following
lights
will
appear:
•
Flashing
Green
and
Yellow
(6
times)
These
lights
indicate
that
the
Resequence
Keycard
worked
properly.
•
Flashing
Yellow
(6
times)
This
light
indicates
that
the
lock
was
not
out
of
sequence.
When
using
a
Resequence
keycard
for
guest
levels,
if
a
red
light
flashes
one
time
before
the
flashing
green/or
yellow
lights,
a
new
Guest
keycard
must
be
made.
Inhibit
Keycard
The
Inhibit
keycard
affects
the
Guest,
Alternate
Guest
and
Failsafe
keycards
and
prevents
the
current
keycards
for
these
keycard
types
from
opening
the
lock.
The
purpose
is
to
prevent
guests
who
have
checked
out
of
the
room
from
later
re
‐
entering
the
room
if
their
keycard
has
not
expired.
It
is
generally
used
after
the
room
has
been
cleaned
and
is
ready
for
the
next
guest.
When
the
Inhibit
keycard
is
used
in
the
lock,
the
following
lights
will
appear:
•
Red
Flash
(1)
Followed
by
Flashing
Yellow
(12
Times)
These
lights
indicate
that
the
Guest
keycards
were
successfully
inhibited,
and
the
current
Guest
‐
level
codes
in
the
lock’s
memory
will
no
longer
allow
entry.
•
Flashing
Yellow
(12
Times)
This
light
indicates
that
the
lock
has
already
been
inhibited.
Electronic
Lockout
Keycard
The
Electronic
Lockout
keycard
is
used
to
double
lock
the
door
from
the
outside
and
prevents
other
keycards
(except
the
Security/Emergency
keycard)
from
activating
the
lock.
The
lock
can
be
programmed
so
that
there
is
one
keycard
to
set
the
electronic
lockout
and
a
separate
keycard
to
remove
the
electronic
lockout,
or
one
toggle
keycard
that
performs
both
functions.
When
the
Electronic
Lockout
keycard
is
used,
the
following
lights
will
appear:
•
Red
Flash
(1)
Followed
by
Flashing
Yellow
(12
Times)
These
lights
indicate
that
the
electronic
lockout
has
been
set.
•
Green
Flash
(1)
Followed
by
Flashing
Yellow
(12
Times)
These
lights
indicate
that
the
electronic
lockout
has
been
removed.
Summary of Contents for Saflok SYSTEM 6000
Page 1: ...REFERENCE MANUAL SYSTEM 6000 ...
Page 2: ...SAFLOK TRAINING AND REFERENCE MANUAL SAFLOK SYSTEM 6000 WINDOWS VERSION 3 ...
Page 4: ...Section 1 Introduction to System 6000 ...
Page 9: ...SECTION 2 System 6000 Installation and Configuration ...
Page 35: ...SECTION 3 Lock and Keycard Features ...
Page 59: ...System 6000 TM Reference Manual_Section 4 Section 4 Lock Operation SAFLOK Page 1 of 16 06_11 ...
Page 75: ...System 6000 TM Reference Manual_Section 5 Section 5 System 6000 Transactions ...
Page 99: ...System 6000 TM Reference Manual_Section 6 Section 6 Diagnostics Error Codes ...