System
6000
TM
Reference
Manual_Section
6
© SAFLOK
Page
26
of
34
06/11
PI
Number/Time
Errors
in
Program
Cycle
Code
Description
063
PI
Number/Time:
The
lock
wasn’t
expecting
PI
Number/Time
key
to
be
used
because
a
PI
clock
key
indicating
PI
Number/Time
key
was
not
just
used.
Contact
SAFLOK
for
assistance.
064
PI
Number/Time:
The
lock
was
expecting
a
PI
Time
key
(AM/PM),
but
PI
key
is
a
Number
key
(0
‐
9).
Contact
SAFLOK
for
assistance.
065
PI
Number/Time:
The
lock
was
expecting
a
PI
Number
key
(0
‐
9),
but
PI
key
is
a
Time
key
(AM/PM).
Contact
SAFLOK
for
assistance.
066
PI
Number/Time:
The
PI
key
has
invalid
values.
Contact
SAFLOK
for
assistance.
General
E2
Errors
That
Should
Not
Occur
Code
Description
103
EPROM
Program
Problem:
Overflow
from
16/8
divide,
replace
circuit
board
immediately.
105
E2
Corrupted:
An
invalid
value
exists
in
the
E2,
replace
circuit
board
immediately.
General
Key
Validation
Errors
Code
Description
112
All
Keys:
The
key
has
invalid
type
values
based
on
its
level.
Contact
SAFLOK
for
assistance.
113
All
Keys:
The
key
is
not
valid
in
the
current
lock
mode
or
cycle.
If
LED
diagnostics
is
on,
turn
off.
Lock
is
typically
in
an
invalid
mode.
Refer
to
Section
3,
Invalid
Lock
Mode
Indicators.
Can
also
occur
if
you
use
Standard
or
Display
keys
when
the
PPK
or
SPK
LEDs
are
flashing.
Contact
SAFLOK
for
assistance.
114
All
Keys:
The
lock’s
property
number
indicates
factory
programming;
key’s
property
number
indicates
that
it
is
a
true
property
key.
You
must
use
Installers/NC
keys
or
reprogram
the
lock.
115
All
Keys:
The
lock’s
property
number
indicates
property
programming;
key’s
property
number
indicates
that
it
is
a
factory
key.
You
must
use
keys
generated
by
your
computer.
116
All
Keys:
The
lock’s
property
number
doesn’t
match
the
key’s
property
number.
Key
is
not
for
this
property.
117
Standard,
Special,
PPK
and
SPK
Keys:
The
lock
is
in
shutdown
cycle
because
10
or
more
invalid
keys
were
used.
A
valid
key
must
be
used
to
terminate
shutdown
mode.
118
Standard,
Special,
PPK
and
SPK
Keys:
The
key’s
record
number
equals
0
(invalid).
Contact
SAFLOK
for
assistance.
119
Standard,
Special,
PPK
and
SPK
Keys:
The
key’s
combination
equals
0
(invalid).
Contact
SAFLOK
for
assistance.
Summary of Contents for Saflok SYSTEM 6000
Page 1: ...REFERENCE MANUAL SYSTEM 6000 ...
Page 2: ...SAFLOK TRAINING AND REFERENCE MANUAL SAFLOK SYSTEM 6000 WINDOWS VERSION 3 ...
Page 4: ...Section 1 Introduction to System 6000 ...
Page 9: ...SECTION 2 System 6000 Installation and Configuration ...
Page 35: ...SECTION 3 Lock and Keycard Features ...
Page 59: ...System 6000 TM Reference Manual_Section 4 Section 4 Lock Operation SAFLOK Page 1 of 16 06_11 ...
Page 75: ...System 6000 TM Reference Manual_Section 5 Section 5 System 6000 Transactions ...
Page 99: ...System 6000 TM Reference Manual_Section 6 Section 6 Diagnostics Error Codes ...