D*AP8
91
"Empty"
Creates a set of empty boxes where you may select the preset of
your choice for the respective function block or leave it empty if no
changes are needed …
Include these Blocks:
[System / Interface / Routing / Dolby Processing /Audio Processor
>
Programs / >AUX / >Delay / >Monitor / Measurement]. You can tell
the event manager which function blocks must be included in this
event (or not).
Important Note!
This is the way to create your own
snap shot
. The new presets will be automatically
given the name of this event! So be careful to select meaningful names. You will find them later on in your
function blocks!
Setup GUI – EVENTS – Events –
Parameter Events
Right now the
D*AP8
supports parameter events to remote control the measurement / logging related
features of the
J*AM
:
The above example selects the category
"Measurement"
with its sub category
"Loudness"
.
From the list of possible parameters, the setting of a marker
"J*AM Marker – Program 1"
has been
selected. This marker will appear in the log file if that preset event is executed. When you press
<create event>
these choices are provided:
Event Name
your choice
Use settings from
[Existing Event / Defaults /
Empty]
Setup GUI – EVENTS – Events –
Measurement Events
A measurement event is used to control the
D*AP8
internal loudness meter.
(See MEASUREMENT > Loudness). For the example below
"Reset"
has been pre-selected for all
possible program configurations and their respective programs: