D*AP8
88
Setup GUI – EVENTS – Triggers – Sources
–
Network
Network triggers are based on the
EmBER+
protocol from Co. l-s-b
http://www.l-s-b.de/en.
The
D*AP8
receives such triggers over the TCP/IP network. The triggers are issued by a device that has
implemented the
EmBER+
protocol (e.g. VSM server, broadcast automation system). You may assign
these triggers to virtual panels as well as physical (e.g. LBP) buttons of a VSM installation. But also a
broadcast automation system may have an
EmBER+
server running that will trigger events in the
D*AP8
.
#
The number of a network trigger.
Label
Label of that network trigger. It will be used on the
Configuration
pane and serves as a reference for 3
rd
party
software implementation (e.g. broadcast automation systems).
As an example you see the name of the first Trigger
"Movie".
<remove>
will remove a line from the list.
The name of the respective trigger may be selected via an
EmBER+
enabled device to fire that
trigger. By means of a setup tool you must configure such network triggers in order to remote control
the
D*AP8
. You will find the Ember+ protocol details, the implementation guidelines as well as an
example here:
code.google.com/p/
ember
-plus/
Below is a screen shot of the
EmBER+
viewer tool:
In the EmBER tree you go to:
"Device" > controller_dsp > network_trigger > parameters > e.g. "idx_1"
As a value you will receive the trigger name from the
D*AP8
.
In this example it is the trigger named:
"Movie"
– the 1
st
trigger
from the example above.