D*AP8
15
Setup GUI – SYSTEM –
System Status
The system status is a special link you can reach independently from where you are :
The
System Status
page provides a top level view of the various status information available for the device.
Device Status
provides the hardware status of the
D*AP8 unit.
Power 1
status of the first power supply (left hand side from rear).
Power 2
status of second power supply (right hand side from rear).
Temperature
measured on the surface of the main PCB.
Sync Lock
turns red if the external sync source is removed or unstable.
NTP Server Status
Is green if the NTP server synchronization is turned off or the clock is
synchronized.
Turns red if the clock can not be synchronized by one of the NTP servers.
Processing Status
Bypass
turns red if Bypass is activated.
Interface Status
AES I/O
turns red if an AES input that is internally in use (i.e. you have routed it to
an input of a function block) has detected an error.
Interface 1 SDI I/O
turns red if the SDI input is not locked (not present or bad SDI signal).
Dolby Processing Status
Decoder (Slot A)
turns orange if the input signal is
not
Dolby encoded (PCM).
Encoder (Slot A)
status of the first D-E encoder (if license is installed).
Metadata
status of the metadata.
Coprocessor Status
turns red if the co-processor encounters a problem.