57 - 1
Synchro Shuttle Gearbox
Forward/Reverse Solenoid Control Valve
Dismantling
Unscrew the knurled nut
2
and remove 'O' ring
3
, withdraw
the solenoid
4
and 'O' ring
5
.
Hold the solenoid valve body
6
in a vice, using the spanner
flats
A
, remove spindle
7
and 'O' ring
8
.
Pull out actuating pin
9
, spring
10
, spring retainer
11
, and
spool
12
.
Inspect the spool and spool bore for signs of wear, nicks
scratches etc.
Assembling
Assembly is reversal of the dismantle procedure.
Renew all 'O' rings.
Lightly lubricate all parts with clean transmission fluid before
assembling.
Check that the flying leads are secure and that the
connectors are intact.
Torque Settings
Item
Nm
kgf m
lbf ft
2
10 to 15
1 to 1.5
8 to 10
Section F
9803/3280
Section F
57 - 1
Issue 1