112 - 14
Section F
9803/3280
Section F
112 - 14
Issue 1
Synchro Shuttle Gearbox
Assembly (cont'd)
Note:
It is recommended that a 75 micron (0.075mm)
service suction strainer (892/00970) is fitted to clean the
system after a major overhaul.
Remove the service strainer and fit a production strainer
after the first 100 hours operation. Renew the oil.
47
Using a new gasket, install suction strainer. Apply JCB
Threadlocker and Sealer to bolts and tighten to 10 Nm
(7 lbf ft).
48
Fit a new filter:
a
Smear seal with transmission oil.
b
Screw the filter on until it just contacts the filter
head.
c
Turn the filter at least another 3/4 of a turn.
49
Install dipstick/oil filler tube (not shown) as follows:
a
Fit nut to tube followed by seal.
b
Insert tube fully down bore in casing. Engage nut
and tighten down loosely onto seal.
c
Tighten nut fully after tube has been correctly
phased.
See
2/4 Wheel Drive Clutch
for hydraulic 4WD
dismantling and assembly procedures.
47
48
A388040
50
50a
50b
50c
50
Fit a new sealing ring
50a
to the pump drive shaft. Insert
the pump drive shaft followed by bearing
50b
and
circlip
50c
.
Note:
The main hydraulic pump may be fitted at this stage,
or, after the gearbox has been refitted to the machine.