Service functions and error messages
Page 148
Error message
Meaning of the error message
Measures
Main
index
Sub index
errors
Action:
Clarify: What is the status of the installed
safety module - does it contain a valid
parameter set?
Read out and analyse the permanent event
memory of the basic device via item Motion
Soft®
Eliminate error causes step by step.
Install safety module with “delivery status”
and perform commissioning of basic device.
If this is not available: Set factory settings in
the safety module, then copy data from the
basic device and perform complete
validation. Check whether the error occurs
again.
5
FSM: Log file - write error
Please contact the Technical Support.
6
FSM: Parameter set - save error
Please contact the Technical Support.
7
FSM: Flash checksum error
Cause:
Voltage interruption / power off while
parameters were being saved.
Flash memory in safety module corrupted
(e.g. by extreme malfunctions).
Action:
Check whether the error recurs after a reset. If it
does:
Parameterise the module again and validate
the parameter set again. If error persists:
Module faulty, replace.
8
FSM: Internal monitoring, processor
1 - 2
Cause:
Serious internal error in the safety module:
Error detected while dynamising internal
signals.
Disrupted programme sequence, stack error
or OP code test failed, processor exception /
interrupt.
Action:
Check whether the error recurs after a reset. If it
does:
Module faulty, replace.
9
FSM: Structure error, invalid software
state
Cause:
Triggering of internal programme sequence
monitoring.