Service functions and error messages
Page 145
Error message
Meaning of the error message
Measures
Main
index
Sub index
1
General error, parameterisation
Cause:
Parameter session active for > 8 hrs.
The safety module has thus terminated the
parameterisation session.
The error message is saved in the permanent
event memory.
Action:
Terminate parameterisation session within 8 hrs.
If necessary, start a new parameterisation
session and continue.
4
Buffer, internal communication
Cause:
Communication connection faulty.
Timeout / data error / incorrect sequence
(packet counter) in data transmission
between the basic device and safety module.
Too much data traffic, new requests are
being sent to safety module before old ones
have been responded to.
Action:
Check communication interfaces, wiring,
screening, etc.
Check whether other devices have read
access to the servo drive and safety module
during a parameterisation session - this may
overload the communication connection.
Check whether the firmware versions of the
safety module and basic device and the
versions of the item Motion Soft® and
SafetyTool are compatible.
5
Communication module - basic device Cause:
Packet counter error during transmission
µC1
µC2
Checksum error during transmission µC1
µC2.