Technical data
Page 37
Table 7:
Technical data: cable specifications
Range
Maximum motor cable length for interference emission as per EN 61800-3
Category C2
Installation in a switch cabinet (see
chapter 8.14 Notes
concerning the safe and EMC-compliant
) to be
performed by a specialist
l
≤
50 m
Category C3
(industrial environment)
l
≤
50 m
Cable capacity of one phase against shield or between two
lines
C‘
≤
200 pF/m
Table 8:
Technical data: motor temperature monitoring system
Motor temperature monitoring system
Values
Digital sensor
N.C. contact:
R
cold
< 500
Ω
R
hot
> 100 k
Ω
Analogue sensor
Silicon temperature sensor, e.g. KTY81, 82 or similar
R
25
≈
2000
Ω
R
100
≈
3400
Ω
4.2
Control elements and display elements
On its front panel, the item Servo Positioning Controller C 3-Series has three LEDs and one seven-segment display to indicate
the operating status.
Table 9:
Display elements and RESET button
Element
Function
Seven-segment display
Indication of the operating mode and of an error code in the event of malfunctions
LED 1 (two-colour LED, green/red)
Operational readiness or errors
LED 2 (green)
Controller enable signal
LED 3 (yellow)
CAN bus status indication
RESET button
Hardware reset for the processor