SECTION 8—BASE REPLACEMENT
49
31. Remove the retaining clip and hour meter from the base (FIGURE 8.6).
32. Using the
5
/
8
open ended wrench remove the nut from the receptacle fitting
33. Remove the receptacle fitting from the base (FIGURE 8.6).
FIGURE 8.6
Base Replacement
34. Perform one of the following (FIGURE 8.7):
• For units manufactured before 10/2/2005:
i. Remove the mounting screw that secures the bracket to the base.
ii. Remove pin partially out.
iii. Lift connector fillport assembly up off of base.
• For units manufactured after 10/2/2005:
i. Remove the two mounting screws that secure the bracket to the base.
ii. Remove pin partially out.
iii. Lift connector fillport assembly up off of base.
Capacitor
Tie Wrap
Mounting Screw
Transformer
Hour Meter
Mounting
Screw
Power
Inlet
Retaining Clip
Receptacle
Fitting
Base
Mounting
Screw