6
TruVision DVR 40 User Manual
Figure 6: Connecting a TVR 40 to a PTZ dome camera
Connection
Serial port TVR 40
I/O box from keypad:
White
D+
Yelow
D-
PTZ camera:
RS-422/RS-485 A
T+
RS-422/RS-485
B
T-
Configure the PTZ protocols for Interlogix cameras
Before the PTZ cameras are assembled in their housings, set their protocol and address DIP
switches for the TVR 40. See Table 1 below for the different Interlogix PTZ camera
configurations.
If you are using PTZ cameras from another company, please refer to their configuration
instructions.
Table 1: Configuring Interlogix PTZ cameras
Camera Switch
setting
TruVision Mini
Dome 12X PTZ:
Indoor Dome
Protocol DIP
switches:
000000
RS-485
communication DIP
switches:
0000000000
Camera ID DIP
switches:
Select the
camera ID
DIP switch
address as
required
1. Protocol DIP switches;
2. RS-485 communication DIP switches;
3. Camera ID DIP switches
RS-485 data connector: