TruVision DVR 40 User Manual
109
Troubleshooting and support
This section provides information to help you diagnose and solve various problems that may
arise while configuring or using your UTC product and offers technical support contacts in case
you need assistance.
Troubleshooting your system
Problem Possible
reasons
POWER LED on front panel does not
light up when the TVR 40 is turned
on, and the fan does not work.
TVR 40 is not connected to the power supply. Check that the power
cable is plugged into the TVR 40.
TVR 40 is not switched on. Check that the power switch on the back
panel is switched on.
The power cable is plugged in and
power is switched on. The POWER
LED on front panel is green but fan
does not work.
Front panel on/off power button is not working.
The fan is broken. The TVR 40 must be sent in for repair.
Please contact your local supplier.
The TVR 40 continuously reboots
after start up, and makes an audible
alarm every 10 seconds.
The wrong firmware has been used in the upgrade.
TVR 40 has hardware problems and must be sent in for repair.
Please contact your local supplier.
When using V
OUT
no images appear
on the monitor when TVR 40 is
turned on.
The cable connected to the monitor is damaged. Check the cable.
TVR 40 has hardware problems. Please contact your local supplier.
The system cannot find the hard disk
in reboot process.
The HDD cable is damaged.
The power cable of the hard disk is not connected.
The HDD is damaged.
Please contact your local supplier.
No response from the HyperTerminal
interface.
The Baud rates of the TVR 40 and PC are different.
RS-232 cable is damaged.
The serial port of the PC is damaged.
RS-232 port of the DVR is damaged.
Please contact your local supplier.
TVR 40 cannot control the PTZ
through the RS-485 port.
RS-485 cable is incorrectly connected or is damaged. Check the
cable.
PTZ parameter error. PTZ settings are incorrect and should be
checked.
RS-485 port of TVR 40 is damaged. Please contact your local
supplier.
Client software cannot view the
TVR 40 live image.
Network error. Please contact your IT manager.
DVR incorrectly configured (for example, incorrect IP, port number,
username or PIN, etc).
Old version of client software. Please contact your local supplier.
Summary of Contents for TruVision DVR 40
Page 1: ...P N TVR40 uman EN REV 2 0 ISS 30SEP11 TruVision DVR 40 User Manual...
Page 6: ...iv...
Page 16: ...10 TruVision DVR 40 User Manual...
Page 26: ...20 TruVision DVR 40 User Manual...
Page 46: ...40 TruVision DVR 40 User Manual...
Page 76: ...70 TruVision DVR 40 User Manual...
Page 84: ...78 TruVision DVR 40 User Manual...
Page 114: ...108 TruVision DVR 40 User Manual...
Page 118: ...112 TruVision DVR 40 User Manual...
Page 122: ......