![Intellinet 560931 User Manual Download Page 64](http://html1.mh-extra.com/html/intellinet/560931/560931_user-manual_2074478064.webp)
64
Indicates the port copy operation of the ACE. Frames matching the ACE are copied to the port number.
The allowed values are
Disabled
or a specific port number. When
Disabled
is displayed, the port copy
operation is disabled.
Mirror
Specify the mirror operation of this port. Frames matching the ACE are mirrored to the destination mirror
port. The allowed values:
Enabled:
Frames received on the port are mirrored.
Disabled
: Frames received on the port are not mirrored.
The default value is "Disabled."
Counter
The counter indicates the number of times the ACE was hit by a frame.
Modification Buttons
You can modify each ACE (Access Control Entry) in the table using the following buttons:
: Inserts a new ACE before the current row.
: Edits the ACE row.
: Moves the ACE up the list.
: Moves the ACE down the list.
: Deletes the ACE.
: The lowest plus sign adds a new entry at the bottom of the ACE listings.
Buttons
Auto-refresh
: Check this box to refresh the page automatically. Automatic refresh occurs at regular
intervals.
Refresh:
Click to refresh the page. Note that non-committed changes will be lost.
Clear:
Click to clear the counter
Remove All
:
Click to remove all ACEs